| Capacity | 30 L |
| Working Temperature | 50 °C to 134 °C |
| Working pressure | 0.217 MPa |
| Working environment | 5 °C to 45 °C |
| Relative Humidity | 10% to 85% |
| Time Setting Range | 0 to 99 h |
| Chamber Thickness | 2.0 mm |
| Power Consumption | 3500 W |
| Power Supply | 220 V, 50/60 Hz |
| Chamber Dimension | Φ350×400 mm |
| Packing Dimension | 790 × 670 × 1160 mm |
| Dimension | 550 × 620 × 1070 mm |
| Net Weight | 92 Kg |
| Gross Weight | 95 Kg |
Safety Interlock Structure
Dual Protection System
Air-Cooled Chilling Device
Automatic Fault Detection
Microcomputer Control
Our Vertical Autoclave includes a water level indicator to ensure proper steam generation, it is designed to safely sterilize surgical instruments, laboratory glassware, culture media, biohazardous waste, textiles, medical equipment.
Download catalog for
Vertical Autoclave LVA-E10 Catalog
Available Range :
Vertical Laboratory Autoclave LVA-C13 : 100 L Vertical Laboratory Autoclave LVA-G13 : 100L Vertical Autoclave LVA-L12 : 110 L Vertical Laboratory Autoclave LVA-C14 : 120 L Vertical Laboratory Autoclave LVA-C15 : 150 L Vertical Autoclave LVA-N13 : 200 L Vertical Autoclave LVA-N10 : 200L Vertical Autoclave LVA-E10 : 30 L Vertical Laboratory Autoclave LVA-C10 : 35 L Vertical Laboratory Autoclave LVA-G10 : 35L Vertical Laboratory Autoclave LVA-K14 : 40 L Vertical Laboratory Autoclave LVA-C11 : 50 L Vertical Laboratory Autoclave LVA-G11 : 50L Vertical Autoclave LVA-L21 : 54 L Vertical Laboratory Autoclave LVA-K10 : 60 L Vertical Laboratory Autoclave LVA-C12 : 75 L Vertical Laboratory Autoclave LVA-G12 : 75L Vertical Laboratory Autoclave LVA-K11 : 80 L Vertical Autoclave LVA-L11 : 85 L
Labtron Vertical Autoclave provide upright design, high pressure steam sterilizer at working temperature of 134℃. Their orientation makes loading and unloading more convenient and efficient. They feature sensors and automatic shut off system enhancing safety by preventing overeating during operation. Their programmable controls enable automatic operation, managing heating, sterilization and cooling phases efficiently. Our Vertical Autoclave effectively eliminates pathogens from glassware and media, ensuring infection control in healthcare settings.








Yes, Vertical Autoclave is specifically designed to sterilize a variety of materials, including both solid and liquid media. This versatility makes it ideal for laboratories, medical facilities, and research centers where different types of materials require sterilization. For solid materials like surgical instruments, glassware, and lab tools, the vertical autoclave uses controlled high temperature (typically 134°C) and pressure (around 0.22 MPa) to kill all microorganisms effectively, including spores, ensuring the items are completely sterilized.When sterilizing liquid media such as culture broths, nutrient solutions, or reagents, the autoclave’s precise temperature and pressure controls are crucial.
Vertical autoclave includes pressure relief valves that prevent dangerous overpressure buildup. Temperature thermostats ensure the sterilization temperature stays within safe limits. They have double-locking lids that prevent the door from being opened while the chamber is pressurized. Low water sensors automatically stop the heating process if the water level is too low. Together, these features protect both the user and the autoclave from accidents and damage.
Vertical Autoclave is designed with user convenience in mind, featuring an intuitive control panel that allows operators to easily select sterilization cycles and monitor the process through a clear digital display. This straightforward interface minimizes the learning curve, making it accessible even for users with limited technical experience. Routine maintenance is simple and essential for ensuring the autoclave’s longevity and optimal performance; it typically involves cleaning the sterilization chamber to remove residue, inspecting and replacing door seals to maintain airtight pressure, and checking the water reservoir.
Vertical Autoclave is equipped with an optimized steam distribution system that ensures even penetration throughout the chamber. This design reduces cold spots, guaranteeing thorough sterilization of all instruments in a single cycle. Additionally, the chamber’s vertical orientation promotes natural steam circulation, enhancing heat and moisture distribution. The autoclave’s sensors continuously monitor pressure and temperature to maintain consistent sterilization conditions throughout the process.
Vertical Autoclave incorporates energy-saving insulation and an intelligent control system that minimizes steam and electricity consumption during standby and active cycles. This not only reduces operating costs but also supports environmentally friendly sterilization practices. Moreover, the autoclave uses rapid heating technology to shorten cycle times, further conserving energy. Its automatic shutdown feature activates after cycles are complete, preventing unnecessary power usage when the unit is idle.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom