Request A Quote
Horizontal Laboratory Autoclave LHA-D37

Horizontal Laboratory Autoclave LHA-D37

Horizontal Laboratory Autoclave LHA-D37 features a temperature range of 105°C to 139°C, ensuring uniform sterilization. With programmable sterilization and drying time of 0 to 999 minutes, it offers high flexibility for varied load types. Featuring a robust double-door design, it ensures contamination-free operation with enhanced safety. It combines high performance and large load handling, making it an ideal solution for demanding sterilization needs.

Horizontal Laboratory Autoclave LHA-D37
Horizontal Laboratory Autoclave LHA-D37
Horizontal Laboratory Autoclave LHA-D37
Request Quote
Chamber Capacity 800 Liters
Door Type Double Door
Control System PLC + HMI + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 52 kg
Water Consumption per Cycle 320 kg
Power Consumption 52 kW
Chamber Size (W × D × H) 652 × 690 × 1800 mm
Outer Dimensions (W × D × H) 1400 × 1950 × 2150 mm
Net Weight 1500 kg
Gross Weight 1800 Kg
  • Large Chamber Capacity
  • Double Door Design
  • Advanced Control System
  • User-Friendly Interface
  • Wide Working Temperature Range
  • High Temperature Accuracy
  • Excellent Temperature Uniformity
  • Programmable Cycles
  • Efficient Vacuum System
  • Strong Vacuum Performance
  • High Safety Standards
  • Energy Efficient
  • Durable and Spacious Build 
  • Heavy-Duty Construction

Our Horizontal Laboratory Autoclave LHA-D37 is specifically designed for the efficient sterilization of high-temperature and high-pressure-resistant items such as unwrapped or wrapped instruments, laboratory glassware, liquids, porous materials, and hollow instruments.

Horizontal Laboratory Autoclave LHA-D37 | Control System: PLC + HMI + Built-in Printer | Safety Valve Opening Pressure: 0.28 MPa
Horizontal Laboratory Autoclave LHA-D37 | Energy Efficient | High Safety Standards

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-G11

Horizontal Laboratory Autoclave LHA-G11

  • Capacity : 200 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0 - 60 minutes
Horizontal Laboratory Autoclave LHA-D11

Horizontal Laboratory Autoclave LHA-D11

  • Capacity : 360 L
  • Design Temperature : 150 ℃
  • Temperature Uniformity : ±1 ℃
  • Max. Working Temperature : 139 ℃
Horizontal Laboratory Autoclave LHA-E11

Horizontal Laboratory Autoclave LHA-E11

  • Capacity : 200 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-F17
Horizontal Laboratory Autoclave LHA-F17
  • Capacity : 10000L
  • Sterilization Temperature : 105°C to 138°C
  • Sterilization Pressure : -0.1 / 0.5 MPa
  • Steam Pressure : 0.3 to 0.5 MPa
Horizontal Laboratory Autoclave LHA-D12
Horizontal Laboratory Autoclave LHA-D12
  • Capacity : 600 L
  • Sterilization Temperature : 139 °C
  • Sterilization Pressure : 0.22MPa
  • Steam Pressure and the Consumption : 0.4 - 0.6 MPa / 30 kg
Horizontal Laboratory Autoclave LHA-B19

Horizontal Laboratory Autoclave LHA-B19

  • Capacity : 300L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
Horizontal Laboratory Autoclave LHA-D22

Horizontal Laboratory Autoclave LHA-D22

  • Capacity : 150L
  • Design Temperature : 150℃
  • Working Temperature Range : 105℃ to 138℃
  • Working Pressure Range : 0 to 0.25 MPa
Horizontal Laboratory Autoclave LHA-D26

Horizontal Laboratory Autoclave LHA-D26

  • Chamber Capacity : 250 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen

Horizontal Laboratory Autoclave LHA-D37 FAQ's
  • The Horizontal Laboratory Autoclave LHA-D37 operates within a wide temperature range of 105°C to 139°C, making it suitable for the effective sterilization of a broad spectrum of materials, including liquids, glassware, instruments, and porous loads. This wide range allows for flexibility in application and ensures microbial inactivation, even in the most challenging sterilization environments.

  • The double-door design of the Horizontal Laboratory Autoclave LHA-D37 supports pass-through installation, typically used in cleanroom environments. It prevents cross-contamination between the sterile and non-sterile zones by allowing materials to be loaded from one side and unloaded from the other after sterilization, maintaining a strict workflow and ensuring the highest hygiene standards.

  • Horizontal Laboratory Autoclave LHA-D37 is engineered to sterilize items that are high temperature and high pressure-resistant, including unwrapped or wrapped surgical instruments, laboratory glassware, liquids, porous materials, and hollow instruments. Its robust temperature and pressure capabilities make it ideal for diverse applications in laboratories, CSSDs, pharmaceutical facilities, and research institutions.

  • Horizontal Laboratory Autoclave LHA-D37 is equipped with a PLC + HMI control system and a 7.0-inch color touchscreen, providing an intuitive interface for monitoring and customizing sterilization and drying parameters. It includes programmable cycles (0–999 minutes) and displays real-time data such as temperature, pressure, and cycle progress, allowing for precise and reliable operation with minimal user training.

  • The Horizontal Laboratory Autoclave LHA-D37 features a liquid ring vacuum pump that supports both pre- and post-vacuum processes. This advanced vacuum system efficiently removes air from the chamber before sterilization and helps with rapid drying after the cycle. The high vacuum rate of –97 kPa ensures optimal penetration of steam into complex load types, including hollow and porous items.

Post your question?

Our experts are here to help!

Horizontal Autoclave:
Horizontal Laboratory Autoclave LHA-G11, Horizontal Laboratory Autoclave LHA-D11, Horizontal Laboratory Autoclave LHA-E11, Horizontal Laboratory Autoclave LHA-F17, Horizontal Laboratory Autoclave LHA-D12, Horizontal Laboratory Autoclave LHA-B19, Horizontal Laboratory Autoclave LHA-D22, Horizontal Laboratory Autoclave LHA-D26, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.