Request A Quote
Vertical Autoclave LVA-O12

Vertical Autoclave LVA-O12

Vertical Autoclave LVA-O12 has a 75 L capacity to handle large volumes efficiently while ensuring reliable performance. It features automatic pressure adjustment for safe and optimized sterilization cycles. The system controls temperature uniformity, maintaining consistent heat distribution throughout the chamber. Its sturdy locking mechanism ensures secure chamber sealing during operation. Our vertical autoclave has a long-lasting heating element that provides extended durability and reduced maintenance needs.

Vertical Autoclave LVA-O12
Vertical Autoclave LVA-O12
Vertical Autoclave LVA-O12
Request Quote
Capacity 75 L
Chamber Volume Ø400 × 625 mm
Working Sterilization Temperature 134℃
Sterilization Temperature 116℃ to 134℃
Working Sterilization Pressure 0.22 MPa
Design Pressure 0.25 MPa
Design Temperature 139℃
Working Pressure 0.22 MPa
Sterilization Time Range 4 to 120 min
Drying Time Range 0 to 240 min
Bucket Dimension 380 × 540 mm
Basket Dimension 360 × 280 × 2 mm
Power Consumption 4.5 kW, AC 220V, 50Hz
Outer Dimension (L × W × H) 525 × 525 × 1190 mm
Packing Dimension (L × W × H) 630 × 680 × 1290 mm
  • Energy-Saving Heating System

  • Fast Sterilization Cycle

  • Built-In Water Tank

  • Silent Operation Mechanism

  • Programmable Sterilization Settings

Vertical Autoclave LVA-O12 is a sterilization device that uses high-pressure saturated steam to disinfect laboratory and medical equipment. It is widely used in microbiology labs, hospitals, and research centers to safely and efficiently sterilize media, glassware, and instruments.



Models of Vertical Autoclave

Labtron Vertical Autoclave provide upright design, high pressure steam sterilizer at working temperature of 134℃. Their orientation makes loading and unloading more convenient and efficient. They feature sensors and automatic shut off system enhancing safety by preventing overeating during operation. Their programmable controls enable automatic operation, managing heating, sterilization and cooling phases efficiently. Our Vertical Autoclave effectively eliminates pathogens from glassware and media, ensuring infection control in healthcare settings.

Vertical Autoclave LVA-P14

Vertical Autoclave LVA-P14

  • Chamber Capacity : 120L
  • Control : PID Processor
  • Display : Digital Display
  • Material : Fully Stainless Steel 304
Vertical Autoclave LVA-E20

Vertical Autoclave LVA-E20

  • Volume of Chamber : 40 L
  • Chamber thickness : 2 mm
  • Working temperature : 50 °C to 134 °C
  • Working pressure : 0.217 MPa
Vertical Autoclave LVA-F22

Vertical Autoclave LVA-F22

  • Capacity : 100 L
  • Sterilization Temperature : 134℃
  • Sterilization Pressure : 0.22 Mpa
  • Time Range : 0 to 99 min or 0 to 99 h 59 min
Vertical Autoclave LVA-D12
Vertical Autoclave LVA-D12
  • Capacity : 75 L
  • Chamber Volume : 400×600 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
Vertical Autoclave LVA-H15
Vertical Autoclave LVA-H15
  • Chamber Capacity : 200 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134℃
  • Sterilization Time : 0 to 99 min or 0 to 99 hr 59 min
Vertical Laboratory Autoclave LVA-I12

Vertical Laboratory Autoclave LVA-I12

  • Capacity : 75 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Chamber Dimension ( Φ × D ) : 388 × 530 mm
Vertical Autoclave LVA-H12

Vertical Autoclave LVA-H12

  • Capacity : 75 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134°C
  • Sterilization Time : 0 to 99 min or 0 to 99 hour 59 min
Vertical Autoclave LVA-A13

Vertical Autoclave LVA-A13

  • Capacity : 100 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Vertical Autoclave LVA-O12 FAQ's
  • Labtron prioritizes safety in all its autoclave designs, incorporating multiple fail-safe features to protect both the user and the equipment. Each vertical autoclave includes automatic pressure release valves that activate if the internal pressure exceeds safe limits, and thermal cut-off mechanisms to prevent overheating. Additionally, the lid locking system ensures the chamber cannot be opened while it is pressurized, preventing any risk of accidental burns or pressure-related injuries. Visual and audio alarms notify users of abnormal conditions. These features work together to deliver safe and compliant sterilization operations.

  • Labtron vertical autoclaves are engineered to deliver even and saturated steam distribution throughout the chamber. This is crucial for ensuring that every item inside whether placed at the top or bottom receives the same sterilization exposure. The autoclaves are fitted with well-positioned steam inlets, powerful heaters, and thermal insulation to maintain consistent internal conditions. In some advanced models, a steam circulator or air removal system ensures there's no trapped air that could lead to ineffective sterilization. This guarantees reproducibility and safety in every cycle, particularly for critical lab processes.

  • Labtron vertical autoclaves come with programmable control systems that allow labs to tailor cycles according to their specific load requirements. Users can set parameters like sterilization temperature, holding time, exhaust speed, and even pre-vacuum or drying cycles in some models. This flexibility enables labs to safely sterilize different materials such as surgical tools, culture media, plastics, or wrapped items all of which require unique conditions. Labtron also allows saving of custom presets, reducing the time and effort for routine sterilizations.

  • Labtron vertical autoclaves are specifically designed to handle both solid and liquid loads, including delicate items like culture media, agar solutions, and buffer preparations. These units feature slow exhaust modes that allow pressure to be released gradually, preventing boiling or spillage of liquids inside the chamber. Additionally, programmable settings enable users to choose precise time and temperature combinations ideal for heat-sensitive liquids, while maintaining complete sterility. This makes Labtron autoclaves versatile for use in microbiology labs, pharmaceutical units, and research facilities.

  • Labtron provides data logging and monitoring options in many of its vertical autoclave models. Some units come equipped with built-in thermal printers, USB ports, or SD card compatibility for storing sterilization records. Others may include PC connectivity or support for external software integration, allowing users to track and document temperature, pressure, and cycle duration. These features are particularly valuable for GLP (Good Laboratory Practices)-compliant labs and regulatory audits, where maintaining sterilization logs is essential for quality assurance and traceability.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608