Vertical Autoclave LVA-O20 is a reliable sterilizer featuring a robust design with dimensions of 670 × 680 × 1230 mm. It is available in a semi-automatic configuration, offering operational flexibility. The internal and external exhaust modes ensure proper steam release and pressure management for safety and efficiency. It includes programmable cycle settings for precise control. Our autoclave is ideal for microbiology labs, research institutions, hospitals, and pharmaceutical industries.

Request Quote
Capacity 30 L
Chamber Volume Φ350 × 400 mm
Chamber Thickness 2.0 mm
Temperature Range 50 °C to 126 °C
Working Environment 5 °C to 45°C
Relative Humidity 10% to 85%
Rated Working Pressure 0.142MPa
Sterilization Time Range 0 to 99 h
Basket Size 330 × 190 mm
Packing Size 810 × 670 × 1260 mm
Dimension 670 × 580 × 1230
Net Weight 95 Kg
Gross Weight 97 Kg
  • Heat- Resistant Outer Shell

  • Single-Touch Sterilization Mode

  • Sterilization Reservation Function

  • Self-Expanding Seal Ring

  • Convenient Drain Valve

Our autoclave is widely used in veterinary clinics, environmental labs, cosmetics testing, textile research, and sterile waste management to ensure safety, effective sterilization, and contamination prevention across diverse professional fields.

Vertical Autoclave LVA-O20 | Capacity: 30 L | Chamber Volume: Φ350 × 400 mm
Vertical Autoclave LVA-O21 | Heat-Resistant Outer Shell | Single-Touch Sterilization Mode

Models of Vertical Autoclave

Labtron Vertical Autoclave provide upright design, high pressure steam sterilizer at working temperature of 134℃. Their orientation makes loading and unloading more convenient and efficient. They feature sensors and automatic shut off system enhancing safety by preventing overeating during operation. Their programmable controls enable automatic operation, managing heating, sterilization and cooling phases efficiently. Our Vertical Autoclave effectively eliminates pathogens from glassware and media, ensuring infection control in healthcare settings.

Vertical Autoclave LVA-L12

Vertical Autoclave LVA-L12

  • Capacity : 110 L
  • Number of baskets : 3
  • Sterilization temperature : 105 °C to 138 °C
  • Working environment temperature : 5 °C to 45 °C
Vertical Autoclave LVA-L10

Vertical Autoclave LVA-L10

  • Capacity : 60 L
  • Number of baskets : 2
  • Sterilization temperature : 105 °C to 138 °C
  • Working environment temperature : 5 °C to 45 °C
Vertical Autoclave LVA-H15

Vertical Autoclave LVA-H15

  • Chamber Capacity : 200 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134℃
  • Sterilization Time : 0 to 99 min or 0 to 99 hr 59 min
Vertical Laboratory Autoclave LVA-J11
Vertical Laboratory Autoclave LVA-J11
  • Capacity : 50 L
  • Sterilization Temperature : 115 to 129 °C
  • Sterilization Pressure : 0.165 MPa
  • Chamber Dimension ( Φ × D ) : 320 × 610 mm
Vertical Autoclave LVA-H13
Vertical Autoclave LVA-H13
  • Capacity : 100 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134°C
  • Sterilization Time : 0 to 99 min or 0 to 99 hour 59 min
Vertical Autoclave LVA-E24

Vertical Autoclave LVA-E24

  • Volume of Chamber : 80 L
  • Chamber thickness : 2 mm
  • Working temperature : 50 °C to 134 °C
  • Working pressure : 0.217 MPa
Vertical Autoclave LVA-H10

Vertical Autoclave LVA-H10

  • Capacity : 35 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134°C
  • Sterilization Time : 0 to 99 min or 0 to 99 hour 59 min
Vertical Autoclave LVA-Q13

Vertical Autoclave LVA-Q13

  • Capacity : 100 L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 100 to 134℃
  • Sterilization Time : 0 to 9999 minutes

Vertical Autoclave LVA-O20 FAQ's
  • Yes, the Vertical Autoclave LVA-O20 is suitable for sterilizing liquid media such as culture broth or saline solutions in sealed, autoclavable containers. It maintains a consistent internal temperature and pressure to ensure complete sterilization without compromising the integrity of the liquid. The programmable cycle settings allow users to adjust holding times to accommodate the thermal inertia of liquids. Users should use vented caps or containers designed for autoclaving liquids to prevent pressure buildup. Proper loading and spacing are essential for even heat distribution.

  • The use of distilled or deionized water is strongly recommended to prevent scale formation on heating elements and internal chamber surfaces. Tap water may contain minerals that can accumulate and interfere with the autoclave’s operation over time. These deposits can reduce efficiency and lead to costly repairs or shortened equipment life. Clean water also ensures accurate sterilization cycles by maintaining steam purity. Regular maintenance, including water reservoir cleaning, further improves performance.

  • Yes, the vertical autoclave features a drying function designed to remove residual moisture from instruments and other materials after sterilization. This function helps prevent microbial growth during storage and ensures the instruments are immediately ready for use or packaging. The drying cycle operates by circulating hot air or residual steam within the chamber. Users can select drying durations based on the type and load of materials. This added functionality improves workflow efficiency in busy lab or clinical settings.

  • The self-expanding seal ring is a critical component that ensures airtight sealing during sterilization cycles. It should be regularly inspected for wear, deformation, or residue buildup. Cleaning the seal with a mild, non-abrasive cleaner extends its lifespan and maintains efficiency. If steam leakage is noticed or the door fails to pressurize, replacement may be necessary. Most users find seal replacement easy and cost-effective with proper guidance from the manual.

  • The Vertical Autoclave LVA-O20 is capable of safely sterilizing biohazardous waste, such as contaminated culture plates, sharps containers, and lab disposables. It ensures pathogens are fully neutralized before disposal, reducing the risk of contamination. The autoclave includes programmable temperature and pressure controls for precise cycle management. Additionally, it supports high-level containment protocols required in biosafety labs. Proper loading and waste packaging are crucial for effective sterilization of hazardous materials.

Post your question?

Our experts are here to help!

Vertical Autoclave:
Vertical Autoclave LVA-L12, Vertical Autoclave LVA-L10, Vertical Autoclave LVA-H15, Vertical Laboratory Autoclave LVA-J11, Vertical Autoclave LVA-H13, Vertical Autoclave LVA-E24, Vertical Autoclave LVA-H10, Vertical Autoclave LVA-Q13, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.