| Capacity | 30 L |
| Chamber Volume | Φ350 × 400 mm |
| Chamber Thickness | 2.0 mm |
| Temperature Range | 50 °C to 126 °C |
| Working Environment | 5 °C to 45°C |
| Relative Humidity | 10% to 85% |
| Rated Working Pressure | 0.142MPa |
| Sterilization Time Range | 0 to 99 h |
| Basket Size | 330 × 190 mm |
| Packing Size | 810 × 670 × 1260 mm |
| Dimension | 670 × 580 × 1230 |
| Net Weight | 95 Kg |
| Gross Weight | 97 Kg |
Heat- Resistant Outer Shell
Single-Touch Sterilization Mode
Sterilization Reservation Function
Self-Expanding Seal Ring
Convenient Drain Valve
Our autoclave is widely used in veterinary clinics, environmental labs, cosmetics testing, textile research, and sterile waste management to ensure safety, effective sterilization, and contamination prevention across diverse professional fields.
Download catalog for
Vertical Autoclave LVA-O20 Catalog
Available Range :
Vertical Autoclave LVA-C13 : 100 L Vertical Laboratory Autoclave LVA-G13 : 100L Vertical Autoclave LVA-L12 : 110 L Vertical Autoclave LVA-C14 : 120 L Vertical Autoclave LVA-C15 : 150 L Vertical Autoclave LVA-N13 : 200 L Vertical Autoclave LVA-N10 : 200L Vertical Autoclave LVA-E10 : 30 L Vertical Autoclave LVA-C10 : 35 L Vertical Laboratory Autoclave LVA-G10 : 35L Vertical Laboratory Autoclave LVA-K14 : 40 L Vertical Autoclave LVA-C11 : 50 L Vertical Laboratory Autoclave LVA-G11 : 50L Vertical Autoclave LVA-L21 : 54 L Vertical Laboratory Autoclave LVA-K10 : 60 L Vertical Autoclave LVA-C12 : 75 L Vertical Laboratory Autoclave LVA-G12 : 75L Vertical Laboratory Autoclave LVA-K11 : 80 L Vertical Autoclave LVA-L11 : 85 L
Labtron Vertical Autoclave provide upright design, high pressure steam sterilizer at working temperature of 134℃. Their orientation makes loading and unloading more convenient and efficient. They feature sensors and automatic shut off system enhancing safety by preventing overeating during operation. Their programmable controls enable automatic operation, managing heating, sterilization and cooling phases efficiently. Our Vertical Autoclave effectively eliminates pathogens from glassware and media, ensuring infection control in healthcare settings.








Yes, the Vertical Autoclave LVA-O20 is suitable for sterilizing liquid media such as culture broth or saline solutions in sealed, autoclavable containers. It maintains a consistent internal temperature and pressure to ensure complete sterilization without compromising the integrity of the liquid. The programmable cycle settings allow users to adjust holding times to accommodate the thermal inertia of liquids. Users should use vented caps or containers designed for autoclaving liquids to prevent pressure buildup. Proper loading and spacing are essential for even heat distribution.
The use of distilled or deionized water is strongly recommended to prevent scale formation on heating elements and internal chamber surfaces. Tap water may contain minerals that can accumulate and interfere with the autoclave’s operation over time. These deposits can reduce efficiency and lead to costly repairs or shortened equipment life. Clean water also ensures accurate sterilization cycles by maintaining steam purity. Regular maintenance, including water reservoir cleaning, further improves performance.
Yes, the vertical autoclave features a drying function designed to remove residual moisture from instruments and other materials after sterilization. This function helps prevent microbial growth during storage and ensures the instruments are immediately ready for use or packaging. The drying cycle operates by circulating hot air or residual steam within the chamber. Users can select drying durations based on the type and load of materials. This added functionality improves workflow efficiency in busy lab or clinical settings.
The self-expanding seal ring is a critical component that ensures airtight sealing during sterilization cycles. It should be regularly inspected for wear, deformation, or residue buildup. Cleaning the seal with a mild, non-abrasive cleaner extends its lifespan and maintains efficiency. If steam leakage is noticed or the door fails to pressurize, replacement may be necessary. Most users find seal replacement easy and cost-effective with proper guidance from the manual.
The Vertical Autoclave LVA-O20 is capable of safely sterilizing biohazardous waste, such as contaminated culture plates, sharps containers, and lab disposables. It ensures pathogens are fully neutralized before disposal, reducing the risk of contamination. The autoclave includes programmable temperature and pressure controls for precise cycle management. Additionally, it supports high-level containment protocols required in biosafety labs. Proper loading and waste packaging are crucial for effective sterilization of hazardous materials.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608