Atomic Absorption Spectrophotometer LAAS-A24 offers a wide wavelength range of 190nm to 900nm. It consists of an 8-lamp turret with fully automatic change and optimization. Includes a modular gas supply system that ensures lower fault rates, higher safety, and reliability. A high-precision mass flow controller is equipped for accurate fuel flow in the flame system. Our absorption spectrometer has an easy one-click automatic optimization feature for multiple analyses of samples.
| Wavelength Range | 190nm to 900nm |
| Light Source | 8-Lamp Turret 2 Positions for High-Performance Lamp |
| Lamp Current Range | 0 To 15ma |
| Optical System Filter | Czemy-Turner Monochromator |
| Diffraction Grating | Groove: 1800 Lines/Mm Blaze Wavelength: 250nm |
| Focal Length | 277mm |
| Spectral Bandwidth | 0.1nm, 0.2nm, 0.4nm, 0.8nm, 1.6nm (Automatic Change) |
| Optical System Features | Automatic Peak-Picking, Spectral Bandwidth Setting, Energy, And Wavelength Optimization |
| Flame System Burner | 10cm Ti Burner Head and Emission Burner |
| Spray Chamber | Direct Forming Spray Chamber |
| Spray Chamber Material | Corrosion-Resistant PPS Material |
| Graphite Furnace System | Heating System Temperatures:3000°C Heating Rate: 2500°C/S |
| Temperature Control Modes | Optical And Constant Voltage |
| Temperature Programming | Slope And Stepped Temperature Programming |
| Separate Control System | For Inner Gas, External Gas, And Make-Up Gas |
| Safety Protection Function | Hardware And Software Dual Alarm Automatic Flame Shut-Off Gas Supply Cut-Off Ignition Failure Alarm Fuel Gas Leakage Alarm Flow Control Errors Alarm Flame Condition, Air Pressure Monitoring |
| Background Correction | D2 Lamp Background Correction S-H Background Correction |
| Correction Ability | Over 30 Times |
| Operation Software | Compatible With Win XP, Win7, Win8, Win10 |
| Max Power Consumption | 0.2kva |
| Power Supply | Single Phase AC, 110V/220V |
| GF Power Consumption | 5.5kva |
| GF Power Supply | Single Phase AC, 220V |
| Dimensions (L × W × H) | 1020 × 530 × 500mm |
| Weight | 85kg |
Atomic Absorption Spectrophotometry is used for the determination of metal concentrations in various samples, including water, soil, and biological materials. It is widely applied in industries such as pharmaceuticals, food and beverage, and mining for quality control and trace metal analysis.
| Accessory name | Quantity |
| HCL Lamp | 1 |
| Accessory name | Quantity |
| HCL Lamp | 1 |
| Standard solution | 1 |
| Hydride Generation | 1 |
| Chiller | 1 |
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608