Automatic Coagulation Analyzer LCAZ-B13 features 48 sample positions, 55 refrigerated and tilted reagent positions for extended reagent use. With a testing speed of up to 280 tests per hour, it ensures rapid and reliable results. It is equipped with dual sampling probes, dual sheathed manipulators, and integrated automatic positioning, enhancing both speed and accuracy. Its four-direction cooling system ensures reliable performance, making it a perfect fit for modern coagulation laboratories.
| Test Methods | Optical Magnetic Beads Immunoturbidimetry Chromogenic Substrate |
| Test Items | PT, APTT, FIB, TT, Coagulation Factors, D-dimer, FDP, ATIII, PS, PC, etc. |
| Test Speed | 280 Tests/hour (Ts/h) |
| Test Channels | 10 |
| Sample Positions | 48 |
| Reagent Positions | 55 (Tilted and Refrigerated) |
| Pre-heating Channels | 20 |
| Cuvette Loading Capacity | 1000 cups |
| Probe | 2 (with liquid surface sensing and constant heating) |
| Washing Stations | 2 |
| Sheathed Manipulators | 2 (Auto-positioning with anti-fall cuvette grip) |
| Sampling Arm | 2 (Integrated Sampling Pump System) |
| Loading System | Drawer-style |
| Calibration | Automatic or Manual |
| Coagulation Curve Display | Yes (Dynamic testing) |
| PT-derived FIB Function | Yes |
| Batch & Emergency Test Capability | Yes |
| Alarm Functions | Cuvette/Reagent/Detergent Insufficiency Abnormal Results Waste Overflow |
| Automatic Retesting Function | Yes |
| Reagent Tilt Design | Yes |
| Bar Code Recognition | Yes |
| Card Reading Function | Inner Card Reader |
| LIS Integration | Yes |
| Data Storage | Infinite (Test & Quality Control Data) |
| Cooling System | Four-directional ventilation and cooling |
| Waste Management | Dedicated Waste Container |
| Product Dimension | 100 × 83 × 83cm |
| Packing Dimension | 115 × 93 × 93cm |
| Net Weight | 150kg |
| Gross Weight | 180kg |
Our Automatic Coagulation Analyzer LCAZ-B13 is widely used in clinical laboratories, hospitals, blood centers, and research institutions for accurate and efficient hemostasis testing.
| Reagent/Consumable Name | Specification | Unit |
| PT (240ts) | Reconstitution Solution: 6×4ml Reagent: 6×4ml Reagent: 6×2ml | Box |
| FIB (240ts) | Buffer: 6×4ml Reagent: 6×2ml | Box |
| TT (240ts) | Reconstitution Solution: 6×4ml Reagent: 6×4ml | Box |
| Routine Control Normal | 10×1ml | Box |
| Routine Control Abnormal | 10×1ml | Box |
| Routine Control High Abnormal | 10×1ml | Box |
| FIB Calibrator | 10×1ml | Box |
| D-Dimer Reagent (160ts) | R1: 4×6ml R2: 4×2ml | Box |
| D-Dimer Control Low | 10×1ml | Box |
| D-Dimer Control High | 10×1ml | Box |
| D-Dimer Calibrator | 12×1ml | Box |
| FDP Reagent (140ts) | R1: 7×2ml R2: 7×2ml | Box |
| FDP Control Low | 10×1ml | Box |
| FDP Control High | 10×1ml | Box |
| FDP Calibrator | 12×1ml | Box |
| X1 Cleaning Solution | 3 Barrels × 5L/Barrel | Carton |
| X2 Cleaning Solution | 10×60ml | Box |
| Quad Test Cup | 960 Ts/Box | Box |
| Magnetic Bead Test Cup | 6 Trays × 1000 Ts/Tray | Carton |
| Waste Box | 30 Pcs | Box |
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608