Automatic Electrolyte Analyzer LAEA-B16 measure parameters like K⁺, Na⁺, Cl⁻, Ca²⁺, Li⁺, and pH from sample volume of just 80µL. It ensures high precision, with a test range for K⁺ of 0.5 to 15.0 mmol/L, and Na⁺ and Cl⁻ from 20.0 to 200.0 mmol/L. The analyzer can store over 10,000 results and includes a standard network configuration. It features an intuitive interface with real-time fault alarms and troubleshooting support, making it easy to use. With a wide measuring range and impressive detection precision, our analyzer is built to deliver dependable performance.
| Sample Type | Plasma, Serum, Whole blood, Urine, CSF |
| Test Parameters | K⁺, Na⁺, Cl ⁻, Ca²⁺, Li⁺, pH |
| Sample Volume | 80µL |
| Test Range | K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Ca²⁺: 0.1 to 5.0 mmol/L Li⁺: 0.0 to 3.0 mmol/L pH: 6.0 to 9.0 |
| Test Precision | K⁺: ≤ 1.0% Na⁺: ≤ 1.0% Cl ⁻: ≤ 1.0% Ca²⁺: ≤ 1.5% Li⁺: ≤ 1.5% pH: ≤ 1.0% |
| Relative Humidity | ≤ 80% |
| Ambient Temperature | 10℃ to 40℃ |
| Atmospheric Pressure | 86kPa to 106kPa |
| Sun Radiation | Avoid direct sunlight |
| Power Consumption | 300VA |
| Power Supply | 100 to 240V, 50/60 Hz |
| Dimension | 340 × 283 × 455 mm |
| Weight | 12 kg |
Our Automatic Electrolyte Analyzer is used in clinical laboratories and hospitals to measure electrolyte levels in blood, urine, and other biological fluids for accurate diagnosis and patient care.
Internal thermal printer × 1 Auxiliary pump tube × 2 Needle for blockage elimination × 1 Connector for calibrating standard solution × 1 Probe tie-in × 2 Electrode O ring × 5 Allen key × 1 Thermo printer paper × 3 Syringe × 1 Fuse × 2 Refill Solution for ISE Electrodes × 5 Refill Solution for Ref Electrode × 1 Calibration standard Solution × 1 Diluent for Urine Sample × 1 Multi-enzyme De-proteinizer 2ml × 3 Electrolytes Quality Control (High/Medium/Low) × 1 Conditioner × 5
Auto sampler (25 sample positions) Auto sampler (25 sample positions) with built-in bar code scanner Calibration standard solution (1280ml) Calibration standard solution ISE+Li (1280ml) K electrode Na electrode Cl electrode Ca electrode pH electrode Li electrode Ref electrode Refill solution for Ref electrode Refill solution for ISE electrodes (K/Na/Cl/Ca/pH) Refill solution for Li electrodes Cleaning solution Conditioning solution Reagent pack connector De-proteinizer (including diluter) for electrodes Electrolytes quality control (High/Medium/Low) Pump tube Printer paper Auto-probe tie in O’ring for electrode Cuvettes for auto sampler × 100
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608