Automatic Potentiometric Titrator LPTT-A13 automates the titration process by precisely measuring the volume of the titrant with a pH range of 0 to 14. Includes pH electrode for titration with suitable connecting cable Allows storage of up to 100 user-defined methods and 10 shortcuts for streamlined operation. Offers automatic calculation using predefined formulas for efficiency. Capable of storing 200 titration data sets in compliance with GLP standards. Features data analysis tools for convenient review, comparison, and recalculation of results.
pH Measuring Range | 0.000 to14.000 pH |
mV Measuring Range | -1999.90 to 1999.90 mV |
Temperature Range | -5.0 to 105.0 ℃ |
Temperature Sensor | 2.25K Ω, NTC |
pH Resolution | 0.001pH |
mV Resolution | 0.01mV |
Temperature Resolution | 0.1 ℃ |
pH Accuracy | ±0.01pH ±1 bit |
mV Accuracy | ±0.03% |
Temperature Accuracy | ±0.3℃ |
Burette Volume Accuracy | 10mlburette: ±0.025ml 20mlburette: ±0.035ml |
Filling Time | 18 sec |
Titration Reproducibility | 0.002 |
Electric Unit Reproducibility | ≤ 0.2mV |
Electric Unit Stability | ±0.3 mV ±1 bit/3h |
Controlling Titration Sensitivity | ±2mV |
Working Environments Temperature | 5.0~35.0 ℃ |
Relative Humidity | ≤ 80% |
Storage | 200 titration data sets |
Communication Interface | RS-232 |
Display | 7-inch vibrant touchscreen |
Display Function | Titration Methods, Curves, And Results |
Dynamic Equivalence-Point Titration (DET) | Yes |
Monotonic Equivalence-Point Titration (MET) | Yes |
Titration To Preset Endpoints with Automatic Conditioning (SET) | Yes |
Calibration With Automatic Buffer Recognition (CAL) | Yes |
Operating System | User, Method, Electrode, Titrant, And Data Management |
Power Supply | 220 ± 22V, 50±1Hz |
Main Dimension | 340×400×400 mm |
Auxiliary Dimension | 200×110×230 mm |
Weight | 10 Kg |
Automatic Potentiometric Titrator is used in quality control in pharmaceuticals, food and beverage analysis, environmental monitoring, chemical process control, water treatment, research and development, petrochemical analysis, etc.
Serial No. | Accessories Name | Quantity |
1 | Automatic Potential Titrator | 1 |
2 | 232-01 reference electrode | 1 |
3 | 213-01 platinum electrode | 1 |
4 | 216-01 sliver electrode | 1 |
5 | 217-01 reference electrode | 1 |
6 | 231-01 pH glass electrode | 1 |
7 | T-818-B-6 ATC probe | 1 |
8 | Burette and infusion tube (SC5.462.023) | 2 |
9 | Beaker (SC8.219.010) | 3 |
10 | Beaker (SC8.463.001) | 3 |
11 | Push rod tool (SC8.227.126) | 1 |
12 | Burette valve system 10mL (SC5.461.044) | 1 |
13 | Stirrer bars(small) | 3 |
14 | Electrode holder system (SC5.108.022) | 1 |
15 | Feeding tube Φ3.2×0.5 | 2 |
16 | Nut GS-14A & B | 3 for each |
17 | Plastic bottle (500ml) | 1 |
18 | FuseΦ5×20(3A) | 2 |
19 | Power line | 1 |
20 | TP-16 printer line | 1 |
21 | USB communication line | 1 |
22 | RS232 communication line | 1 |
23 | 7.0 touch pen | 1 |
24 | pH buffer4/7/10 | 5bags each |
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608