Flammability Tester LFLC-A14 is a comprehensive solution for assessing fire resistance of plastic and non-metallic materials. It has gas pressure of 0.1Mpa for effective functioning of the tester. Designed with integral type inlet ignition system to ensure safe operation. Multi-functional flame measure gauge provides accurate flame characterization. High precision digital indicator delivers reliable measurements.
Blast Burner Standard | IEC60695-11-3/IEC60695-11-4/10, UL94, inner diameter:Φ9.5±0.3mm,length:100 mm, made of brass |
Gas Pressure | 0.1 Mpa |
Gas Flow | 50W:105 ± 5ml/min or 18 ± 1mm;500W:965±30ml/min or 117 ± 3 mm, flow meter adjustment |
U type pressure gauge back pressure water column height | 50 W:10 mm, 500 W: 125 ± 5 mm |
Test Angle | 50 W: 0°, 45°; 500 W: 20 ° |
Burning Time | 0-9999×0.1 S (Can be preset) |
Residual Flame | 0-9999×0.1S (Can be displayed) |
Test Flame Calibration | Temperature measuring copper head:50W:Ф5.5 mm ± 0.01 mm, weight before drilling: 10 ± 0.05 g |
Thermocouple Temperature Resistance | 1100° |
Distance between the bunsen burner port to temperature measuring copper block | 50 W: 10 ± 1 mm; 500 W: 55 ± 1 mm |
Flame Height |
50W: 20 ± 2 mm (there is no internal and external flame); 500W: Inner flame: 40 ± 2mm,Outer flame:125 ± 10 mm |
Temperature Rise Time | From 100 ± 2° to 700°± 3° 50W: 44 ± 2S |
Test Chamber | > 0.75 cube, black in wall, with exhaust fan |
Power Supply | 220 V/50 Hz |
Power | 50W and 500W double power switching |
Control Mode Operation | PLC control, 7-inch color touch screen operation, with infrared remote control |
Dimension | 1150 × 600 × 1260 mm |
Packaging Dimension | 1210 × 660 × 1420 mm |
Weight | 165 Kg |
Flammability Tester is used across electronics manufacturing, automotives, construction sector, aerospace, etc.