Gel Documentation System LBGD-A16 features a 9-megapixel SCMOS camera that delivers highly detailed images with exceptional sensitivity. Its low-noise design minimizes background interference for cleaner, more accurate results. The optimized pixel sensor improves resolution and light sensitivity, producing sharp and clear gel and blot images. Our Gel Documentation System is ideal for CF488, CY2, CY3 fluorophore detection, gel documentation, and western blotting.
| Pixel Dimensions | 3.76 × 3.76 µm |
| Resolution | 9 Megapixels (3000 × 3000) |
| Camera Type | Cooled SCMOS Camera |
| Readout Noise | 2 e⁻ RMS at 12 MHz |
| Dark Current | Less than 0.00015 e⁻/Pixel/sec at -30°C |
| Quantum Efficiency (QE) | 90 % |
| Dynamic Range | 4.8 OD |
| Pixel Density | 16-Bit (65,536 Grey Scales) |
| Cooling System | Three-Stage Cooling |
| Lens Type | F0.95 Fast Lens |
| Lens Control | Software-Controlled Zoom |
| Focus Options | Autofocus and Manual Focus |
| Darkroom Type | Light-Tight Chamber |
| Sample Tray Layers | Four-Layer for Chemiluminescence |
| Chemiluminescence Imaging Area | 180 × 160 mm |
| UV Transilluminator | 210 × 260 mm (302 nm) |
| White Light Plate | 190 × 260 mm |
| Fluorescence Plate | 180 × 160 mm |
| Illumination – White | Dual Epi-White LED |
| Illumination – Blue | Dual Epi-Blue LED (CF488, CY2) |
| Illumination –Green | Dual Epi-Green LED (CY3) |
| Filter Wheel | 5-Position Motorized Filter Wheel |
| Standard Filter Wavelength | 590 nm |
| CF488 and CY2 Filter Wavelength | 515 nm/ 20 Filter, 505 to 525 nm |
| CY3 Filter Wavelength | 575 nm/ 20 Filter,565 to 585 nm |
| Interface | USB 3.0 |
| Software | Image Acquisition Software and Image Analysis Software |
| Operating Temperature | 10°C to 35°C |
| Operating Humidity | 20 to 80% RH (Non-Condensing) |
| Power Supply | AC 110 to 240 V, 50/60 Hz |
| Power Consumption | 150 W |
| Dimensions (L × D × H) | 430 × 360 × 700 mm |
| Weight | 40 kg |
Gel Documentation System LBGD-A16 enables precise imaging and analysis of DNA, RNA, protein gels, and blot membranes using a high-sensitivity cooled SCOMS camera. It is designed for gel documentation, western blot imaging, SDS-PAGE protein analysis, chemiluminescence detection, and multi-colour fluorescence applications.
Name | Quantity |
UV Transilluminator | 1 piece |
White Light Transmission | 1 piece |
Epi- Blue Fluorescence module | 1 piece |
Epi- Green Fluorescence module | 1 piece |
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608