Heated Lid Dry Bath Incubator LHDI-B11 is a compact design with a temperature range of -10 °C to 100 °C. It features a multi-point operation mode for enhanced precision and efficiency. The incubator incorporates an adjustable heating lid, which ensures uniform heat distribution and prevents sample evaporation. Its integrated temperature sensor and heating/cooling function deliver rapid and accurate temperature control. Our Incubator is widely used for sample incubation, nucleic acid denaturation, enzyme reactions, and PCR preparation.
| Temperature Setting Range | -10 °C to 100 °C |
| Temperature Control Range | RT -25 ℃ to 100 ℃ |
| Temperature Accuracy | Up to ±0.3 ℃ at 37 ℃ |
| Temperature Uniformity | Up to ±0.3 ℃ at 37 ℃ |
| Heating Time | Up to 12 min (from 25 ℃ to 100 ℃) |
| Cooling Time | Up to 12 min (from 100 ℃ to 25 ℃) Up to 25 min (from RT to RT -25 ℃) |
| Timing Range | 1 sec to 99 h 59 min/ ∞ |
| Heating Lid Temperature Setting Range | OFF to +10 ℃ |
| Heating Lid Temperature Accuracy | Up to ±0.5 ℃ |
| Heating Lid Heating Time | Up to 10 min (from 25 ℃ to 100 ℃) |
| Multi-point Running | Yes (max 5 points) |
| Multi Cycle | Yes (max 99 times) |
| Storage at 4 ℃ | Yes |
| Auto Running | Yes |
| Auto Resume To Run | Yes |
| Auto Heating | Yes |
| Power Requirements | AC 220 V or AC 100 V/ 50 to 60 Hz, 150 W |
| Fuse | 250 V 3A Ф5 × 20 |
| Dimensions | 300 × 200 × 210 mm |
| Net Weight | 4.7 Kg |
Our Heated Lid Dry Bath Incubator LHDI-B11 is ideal for sample incubation, nucleic acid denaturation, enzyme reactions, and PCR preparation. The integrated heating lid makes it especially suitable for processes involving PCR tubes and microplates, minimizing condensation and improving reaction stability. Its interchangeable block compatibility makes it a flexible tool for molecular biology, clinical diagnostics, and biochemical laboratories.
| No. | Description |
| Block 01 (Heating and Cooling) | 2.0 mL × 35 (RT -25℃ to 100℃) |
| Block 02 (Heating and Cooling) | 1.5 mL × 35 (RT -25℃ to 100℃) |
| Block 03 (Heating and Cooling) | 0.5 mL × 54(RT -25℃ to 100℃) |
| Block 04 (Heating and Cooling) | 0.2 mL × 96 PCR (RT -25℃ to 100℃) |
| Block 05 (Heating and Cooling) | 0.2 mL × 96 ELISA (RT -25℃ to 100℃) |
| Block 06 (Only heating) | 2.0 mL × 35 (RT +5℃ to 100℃) |
| Block 07 (Only heating) | 1.5 mL × 35 (RT +5℃ to 100℃) |
| Block 08 (Only heating) | 0.5 mL × 54 (RT +5℃ to 100℃) |
| Block 09 (Only heating) | 0.2 mL × 96 PCR (RT +5℃ to 100℃) |
| Block 10 (Only heating) | 0.2 mL × 96 ELISA (RT +5℃ to 100℃) |
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608