Refrigerated Centrifuge LRF-B41 comes with a maximum speed of 5500 rpm and a maximum RCF of 4919 ×g for efficient separation. It features a noise reduction system for quieter operation during centrifugation. The rotor's automatic identification system ensures accurate and safe operation. This unit includes a one-key short-time centrifuge button for quick and easy operation. Our Refrigerated Centrifuge provides an AC frequency conversion brushless motor for efficient performance.
| Max Speed | 5500 rpm |
| Max RCF | 4919 ×g |
| Max Capacity | 4 × 250 ml |
| Timer | 1s to 99h 59min 59s |
| Revolutions/min | ±10r/min |
| Temp Range | -20℃ to 40℃ |
| Temp Accuracy | ±1.0℃ |
| Noise Level | ≤ 60 dB (A) |
| Power Consumption | 1 KW |
| Power Supply | AC 220 ± 22V, 50Hz, 10A |
| Dimensions (W × D × H) | 660 × 600 × 360 (mm) |
| Weight | 86 kg |
Equipped with five programmable groups
Incorporates program shortcut keys
Automatic electronic door lock
Ensures low opening height
Integrated with auto lid lock
Refrigerated Centrifuge LRF-B41 is used to separate substances at lower temperatures and to prevent heat buildup during the centrifugation process. It is mainly used in Biotechnology and Molecular Biology, Clinical Laboratories, Pharmaceutical Research, Environmental Testing, and Forensic and Diagnostic Laboratories
Rotor Model | Max Speed (rpm) | Capacity (ml) | Max. RCF (×g) |
Angle rotor 01 | 5500rpm | 6×50ml(W) | 3645×g |
Angle rotor 02 | 5000rpm | 40×15ml(W) | 4919×g |
Swing-out Rotor 01 | 4000rpm | 4×50ml | 2951×g |
Swing-out Rotor 02 | 4000rpm | 4×100ml | 2951×g |
Swing-out Rotor 03 | 4000rpm | 8×50ml | 2951×g |
Swing-out Rotor 04 | 4000rpm | 8×100ml | 2951×g |
Swing-out Rotor 05 | 4000rpm | 16×10/15ml (Optional) | 2951×g |
Swing-out Rotor 06 | 4000rpm | 24×10/15ml (Optional) | 2951×g |
Swing-out Rotor 07 | 4000rpm | 32×10/15ml (Optional) | 2951×g |
Swing-out Rotor 08 | 4000rpm | 48×2 to 7ml (Blood collection tube) | 2951×g |
Swing-out Rotor 09 | 4000rpm | 64×5ml (Blood collection tube) | 2951×g |
Swing-out Rotor 10 | 4000rpm | 4×250ml (Round bucket) | 3040×g |
Swing-out Rotor 11 | 4000rpm | 4×250ml (Round bucket) (with biosafety lid) | 3040×g |
Swing-out Rotor 12 | 4000rpm | Auto uncap 64×2-7ml (blood collection tube) | 3040×g |
Swing-out Rotor 13 | 4000rpm | 4×250ml (Square bucket) | 3040×g |
Swing-out Rotor 14 | 4000rpm | Micro-plate 2×2×96 hole | 2057×g |
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608