Labtron Analytical HPLC System LAHS-A10 is a complete high performance liquid chromatography system for separating, identifying, and quantifying compounds in routine and research analysis. A quaternary low-pressure pump blends up to four solvents for flexible gradient elution, delivering flow rates from 0.001 to 10 ml/min in 0.001 ml steps at pressures up to 63 MPa, with low pulsation for stable baselines. A built-in vacuum degasser removes dissolved gases for smooth, consistent flow. The UV-Vis detector covers 190 to 800 nm using deuterium and tungsten lamps, so this HPLC machine handles a broad range of compounds with low baseline noise and drift. Chromatography software includes internal and external standard calculation and displays, prints, and exports data automatically, and it can start the next method when a run finishes. Optional column oven, autosampler, and diode array, refractive index, evaporative light scattering, and fluorescence detectors let the system grow with your applications. Analytical HPLC System LAHS-A10 suits pharmaceutical, food, environmental, chemical, and water analysis laboratories.
| Pump Type | Quaternary Low-Pressure Pump |
| Pump Flow Rate Range | 0.001 to 10.000 ml/min, in 0.001ml increments |
| Pump Flow Accuracy | ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa) |
| Pump Flow Precision | RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5Mpa) |
| Pump Maximum Pressure | 63 Mpa |
| Pump Pressure Accuracy | ≤ ± 3.0 % |
| Pump Pressure Pulsation | ≤ 0.1 Mpa |
| Pump Composition Range | 0 to 100 % |
| Pump Composition Precision | ≤ 0.3 % RSD |
| Uv/Vis Detector Wavelength Range | 190 to 800 nm |
| Detector Wavelength Repeatability | ≤.1 nm |
| Detector Wavelength Accuracy | ≤ ± 1.0 nm |
| Detector Band Width | 6 nm |
| Detector Response Time | 0.0 s to 5 s |
| Detector Baseline Noise | ≤ ± 0.25 × 10-5 AU (empty cell, 254 nm, 1.0s) |
| Detector Drift | ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min) |
| Detector Path Length | 10 mm (analytical cell) |
| Detector Light Source | Deuterium Lamp and Tungsten Lamp |
| Column Oven Capacity | 3 column |
| Column Oven Thickness | ID10 × 250 mm |
| Conditions | 21 CFR part 11 directive of the FDA |
| System Kits | 1 Set (A/D converters 4-channel vacuum degasser) |
| Power Supply | AC 110 /220 V ±10%, 50/60 Hz |
| Internal Dimension | 710 × 583× 500mm |
| External Dimension | 770 × 450 × 700 mm |
| Weight | 156 kg |
Our analytical HPLC system is widely used in food, medicine, environmental protection and scientific research.