Atomic Absorption Spectrophotometer LAAS-A23 provides low detection limit of 0.4 x 10⁻¹² g for Cadmium, capable of detecting copper at levels as low as 0.002 µg/mL. The fully closed optical system protects the optics from dust and corrosive laboratory atmospheres, ensuring longevity and stability. This spectrophotometer enhances sensitivity and extends the life of your graphite tubes, making high-performance analysis more efficient than ever. It uses an imported photomultiplier tube (PMT) for high signal-to-noise ratio and sensitive detection. Our LAAS-A23 is ideally suited for ultra-trace metal analysis in environmental monitoring.
| Wavelength range | 185 to 900 nm |
| Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 0.7 nm, 1.0 nm, 1.4 nm, 2.0 nm automatic setting |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength repeatability | < 0.1 nm |
| Baseline Stability | ≤ ± 0.002 A/30 min (Static), ≤ ± 0.004 A/30 min (Dynamic) |
| Absorbance Range | 0 to 4 A |
| The Program | Automatic temperature controls up to 20 order |
| Temperature Range | Room temperature to 3000 ℃ |
| Detector | Imported photomultiplier tube |
| Heating Mode | Vertical heating |
| Temperature Control Method | Vertical optical temperature monitoring graphite tube wall temperature |
| Temperature Control | The furnace enriched up to 20 times |
| Lamp holder | ≤ 8 lamps automatic turret, automatic alignment |
| Lamp power supply mode | Pulsed power supply |
| Optical System | Large 1800 /mm grating ruling, full closed optical system |
| Atomization Chamber | Polymer explosion-proof spray chamber |
| Characteristics Volume | 0.4 × 10-12g (Cd) |
| Detection Limit | 0.4 × 10-12g (Cd) |
| Detection Limit (Cu) | 0.002 μg/mL |
| Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
| Nebulizer | Atomizer efficient glass atomizer, can also be customized |
| Precision | RSD ≤ 0.5 |
| Ignition Type | Microcomputer control, automatic ignition |
| Safety measures | Graphite tube damage, water flow Air pressure and other alarm temperature overheating protection |
| Gas Control | Automatic gas control system |
| Cooling Water | Can choose cooling water circulation system |
| Power supply | 110 / 220 V (+5 % to -10 %), 60 / 50 Hz; 5000 VA |
Broad Wavelength Range
High-Resolution Monochromator
Vertical Heating Mode
Wide Temperature Range
High-Sensitivity Detector
Ultra-Low Detection Limits
Automatic Gas Control
Robust Spray Chamber
Durable Burner Head
Comprehensive Safety Alarm System
Flexible Cooling Options
PMT Detector for High Sensitivity
Explosion-Proof Polymer Spray Chamber
Our Atomic Absorption Spectrophotometer LAAS-A23 is ideally suited for ultra-trace metal analysis in environmental monitoring, ensuring compliance by detecting heavy metals like lead and cadmium in water and soil at parts-per-billion levels. Furthermore, its high precision and sensitivity make it an indispensable tool for clinical and biological research, analyzing metal concentrations in tissues and bodily fluids.
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608