Atomic Absorption Spectrophotometer LAAS-A26 features an automatically adjustable spectral bandwidth of 0.1, 0.2, 0.4, 1.0, and 2.0nm for precise element analysis. Its high-intensity hollow cathode lamps provide accurate and stable light sources for element analysis. Includes flame atomizer to ensure efficient sample atomization for enhanced sensitivity in quantitative metal analysis. Feature graphite furnace that enables ultra-trace element detection with improved accuracy and lower detection limits. The deuterium background correction minimizes interference, ensuring accurate readings in complex sample matrices.
| Wavelength Range | 190 to 900nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0nm (automatic adjustable) |
| Wavelength Accuracy | ±0.15nm |
| Wavelength Repeatability | ±0.1nm |
| Baseline Stability | ≤0.002A/30 minutes (static); ≤0.005A/30 minutes (dynamic) |
| Grating | 1800mm |
| Environment Temperature | +15°C to +35°C |
| Relative Humidity | 20% to 80% |
| Light Source | 6-lamp automatic turret, automatic alignment |
| Characteristic Concentration (Cu) | 0.015μg/mL/1% |
| Detection limits (Cu) | 0.002μg/mL |
| Precision | RSD≤0.5% |
| Background Correction | Correction of 1A background |
| Measurement Methods | Flame method, hydride method |
| Repetition Frequency | 1 to 99 times |
| Interface | Computer and USB interface communication |
| Power Consumption | 6kW |
| Power Supply | 220V (±5% to -10%), 50/60 Hz; 5000VA |
| Product Dimension (L×W×H) | 990 mm× 430 mm× 410 mm |
| Packaging Dimension (L×W×H) | 1260 mm× 640 mm× 70 mm |
| Net Weight | 100kg |
| Gross Weight | 120kg |
Efficient glass atomizer with spray chamber
Includes Metal titanium combustion head
Double cathode power built-in high-performance lamps
Automatic PC control alignment, optimization, ignition
Automatic safety protection function
Anti-temperature/automatic gas path protection
Deuterium background correction
Our Atomic Absorption Spectrophotometer LAAS-A26 precisely measures trace metal concentrations in pharmaceuticals, food safety, environmental monitoring, and industrial quality control, ensuring accurate, reliable, and reproducible analytical results.
HCL Lamp (Pb,Cd,Cu) 3pc
Hollow cathode lamp
Graphite tube
Main unit dust cover
3A fuse wire
1.5A fuse wire
Three core power line
Main Unit Signal Line
Plastic Pipe
Screwdriver
Acetylene hose clip
Acetylene gas pipe
Desktop Computer
Printer
Oil-less Air Compressor
Graphite System
HCL Lamp (Se, Fe, Mn, Zn, Na, K)
Hydride Generator
Water Chiller
Cooling Water System
Auto Sampler (Flame)
Auto Sampler (Graphite Furnace)
Auto Sampler (Flame and Graphite Furnace)
Glass Atomizer
Adjustable Atomizer (1-10 mL)
Hydrofluoric Acid Resistant Type Atomizer
Electrically Heated Quartz Tube (Normal)
Electrically Heated Quartz Tube (White Porcelain)
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608