Genetic Analyzer LGA-A10 uses capillary electrophoresis to detect genetic variations accurately and supports up to 16 channels. It detects single-base mutations, SNPs, and copy number variations using only 20 ng of human genomic DNA. The analyzer delivers results within 24 hours and can analyze up to 60 probes per reaction. Its open software platform is compatible with various MLPA kits, offering flexibility for multiple applications. Our analyzer is used for MLPA, Sanger Sequencing, and Fragment Analysis.
| Detection Method | Capillary electrophoresis |
| Channels | 16 |
| Capillary Length | 36 cm, 50 cm |
| Fluorescence Detection | 6 |
| Tests Throughput | 576 tests per day |
| Laser Type | Semiconductor Laser |
| Laser Wavelength | 505 nm |
| Fluorescent Dye Range | More than 520 nm |
| Read Length | More than 800 bp |
| Temperature Accuracy | ±0.2℃ |
| Resolution | 1 bp |
| Sample Tray | 96-well format |
| Sample Injection | Automated |
| Operating Temperature | 10℃ to 30℃ (± 2℃ fluctuation) |
| Humidity Range | 40% to 60% (non-condensing) |
| Atmospheric Pressure | 86 to 106 kPa |
| Software Versions | Embedded v2.1, External v2.0 |
| Output | Electrophoresis patterns, fluorescence maps |
| Power Supply | AC 220 V 50 Hz, single-phase, 10 A, 2200 VA |
| Item Delivered | Wooden box, carton, polystyrene box 1, polystyrene box 2 |
| Wooden Box Contents | Genetic Analyzer |
| Carton Contents | Power cable, internet cable, wireless network card, buffer reservoir, buffer reservoir septa, 96-well sample tray, 96-well septa, pump block upper dip tray, polymer block lower dip tray, polymer injection pump, polymer lower block, polymer tube, syringe, capillary array(16 channel) |
| Polystyrene Box 1 Contents | POP7, buffer 10X, HD formamide, 6-dye matrix |
| Polystyrene Box 2 Contents | Orange-600, DS-33 spectral calibration kit |
| Genetic Analyzer Dimension (Closed) | 610 × 532 × 812 mm |
| Genetic Analyzer Dimension (Open) | 1225 × 532 × 812 mm |
| Packing Dimension | Wooden Box: 770 × 692 × 1062 mm Carton: 610 × 430 × 131 mm Polystyrene Box 1: 380 × 320 × 300 mm Polystyrene Box 2: 330 × 250 × 280 mm |
| Genetic Analyzer Net Weight | 95 Kg |
| Gross Weight | Wooden Box: 128 kg Cartoon: 6 kg Polystyrene Box 1: 1 kg Polystyrene Box 2: 2 kg |
Automatic polymer injection
Automatic sample handling
Self-developed data acquisition and analysis software
Customizable language interface and free software upgrades
Cost-efficient performance
Benchtop design
Our Genetic Analyzer LGA-A10 is detects genetic variations like deletions and duplications. It is used in clinical diagnostics, cancer research, prenatal screening, and genetic disorder studies.
Name | Quantity |
| Genetic Analyzer | 1 unit |
| Power cable | 1 unit |
| Internet cable | 1 unit |
| Wireless network card | 1 unit |
| Buffer Reservoir | 3 units |
| Buffer Reservoir Septa | 3 units |
| 96-Well Sample Tray | 3 units |
| 96-Well Septa | 10 units |
| Pump Block Upper Drip Tray | 1 unit |
| Polymer Block Lower Drip Tray | 1 unit |
| Polymer Injection Pump | 1 unit |
| Polymer Lower Block | 1 unit |
| Polymer Tube | 1 unit |
| Syringe | 1 unit |
| Capillary Array, 16-channel (50 cm) | 2 units |
| Polymer separation gel 07 (7ml, 2℃~8℃) | 2 bottle |
| Buffer 10X (28ml, 2℃~8℃) | 1 bottle |
| HD formamide (7ml, -25℃~-15℃) | 1 bottle |
| 6-dye Matrix (6 colors) (50μL, -25℃~-15℃) | 1 bottle |
| Orange 600- Fluorescent DNA size marker (600 bp band) (50μL, -25℃~-15℃) × 1 unit | 1 unit |
| Spectral Calibration Kit (15μL-25℃~-15℃) | 1 unit |
Name | Quantity | Usage Guideline | Function |
96-well PCR plate | Pack (10 pices) | - | 200UL ,96-Well |
16-Well,Buffer Reservoir Septa | Pack (20 pices) | - | Adhesive septa for use with buffer reservoir |
96-Well Septa | Pack (10 pieces) | - | Sampling septa for use with 96-well plates |
16-capillary array (36 cm) | Set (36 cm) | Replace after every 200 uses | Containers for electrophoresis for fragment |
16-capillary array (50 cm) | Set (50 cm) | Replace after every 200 uses | Containers for electrophoresis for fragment |
Buffer 10X | Bottle (500 mL) | Change once a week, 5 mL each time | Provides ion concentration and maintains PH |
HiDi Formamide | Bottle (25 mL) | Suitable for about 2500 samples | Denaturant that prevents the sequencing |
Polymer separation gel 05 | Bottle (3.5 mL) | Change every week and add ateleast 1.5 mLeach time | Can be used for genetic analysis on |
Polymer separation gel 07 | Bottle (28 mL) | Change every week and add ateleast 1.5 mLeach time | used for genetic analysis on sequencers |
Orange500- Fluorescent DNA size marker (500 bp band) | Set (120 µL × 2) | Suitable for about 200 experiments | Used as a molecular weight internal standard |
Orange600- Fluorescent DNA size marker (600 bp band) | Piece (50 µL) | Suitable for about 220 experiments | Used as a molecular weight internal standard |
SG Terminator V1.8 Cycle Sequencing Kit (192 µL) | Piece (192 µL) | Suitable for 24 reactions | Sanger sequencing cycle sequencing uses |
SG Terminator V1.8 Cycle Sequencing Kit (800 µL) | Piece (800 µL) | Suitable for 100 reactions | Sanger sequencing cycle sequencing uses |
SG Terminator V1.8 Cycle Sequencing Kit (8000 µL) | Piece (8000 µL) | Suitable for 1000 reactions | Sanger sequencing cycle sequencing uses |
SG Terminator V1.8 Cycle Sequencing Kit (2 Bottles) | Bottle (2 × 20 mL) | Suitable for 5000 reactions | Sanger sequencing cycle sequencing uses |
Gene-Sequencing Performance Metrics | |||||
Running Mode | Avg. Run Time (min) | Max Throughput (samples/day) | Capillary Length (cm) | Rubber Type | CRL (bp) |
Sequence36_SY07 | 35 | 656 | 36 | SY07 | 500 |
Sequence50_SY07 | 120 | 192 | 50 | SY07 | 850 |
Fastseq50_SY07 | 60 | 384 | 50 | SY07 | 700 |
Fragment Analysis Performance | |||||||||
| Running Mode | Flux | Consumptive Material | Function | ||||||
General Performance | Fragment Size Analysis Accuracy (Standrad Deviation) | ||||||||
Avg. Running Time (min) | Max. Throughput (sample/day) | Capillary Length (cm) | Rubber Type | Resolution Range | Longest Fragment that can be analysed | 500 to 400 bp | 401 to 640 bp | 640 to 1200 bp | |
| GeneScan36_SY04 | 50 | 448 | 36 | SY04 | 40–640 bp | 640 bp | <0.15 | <0.3 | N/A |
| GeneScan36_SY07 | 35 | 656 | 36 | SY07 | 40–640 bp | 640 bp | <0.15 | <0.3 | N/A |
| GeneScan50_SY07 | 45 | 512 | 50 | SY07 | 40–640 bp | 640 bp | <0.15 | <0.3 | N/A |
| GeneScan50_SY07Long | 125 | 176 | 50 | SY07 | 40–1200 bp | 1200 bp | <0.15 | <0.3 | <0.35 |