Genetic Analyzer LGA-A11 uses capillary electrophoresis and laser-induced fluorescence detection methods and supports 24-channel sample processing. It employs integrated data collection software tailored for forensic workflows. The analyzer uses an automatic polymer injection and has a capacity for 96-well plates or 8-strip tubes. Also, it is capable of performing 760 tests per day. Our analyzer provides forensic-specific analysis software with real-time data assessment and automated STR interpretation.
| Detection Method | Capillary electrophoresis and Laser-induced fluorescence detection |
| Channels | 24 |
| Fluorescent Dyes | 6 real-time detection (expandable to 10) |
| Samples Per Run | 24 |
| Average Run Time | Less than 45 minutes |
| Max Samples Per Day | 760 |
| Entry Method | Fully automatic injection; supports 96-well plates and 8 exhaust pipes |
| Rubber Injection Method | Fully automatic glue injection |
| Laser Light Source | 505 nm solid-state laser |
| Fluorescence Detection Wavelength | More than 520 nm |
| Resolution | 1 bp, read length up to 800 bp |
| Temperature Control Accuracy | Below 0.2°C |
| Permissible Temperature Range | 20 to 30°C (fluctuation during operation up to ± 2°C) |
| Permissible Humidity | 20 to 60% (non-condensing) |
| Atmospheric Pressure | 86 to 106 kPa |
| Connectivity | USB, Ethernet, Cloud Connectivity |
| Data Integration | LIMS Integration |
| Software | GMIDX, Genotyping |
| Operational Capacity | 48-hour Operation |
| Power Supply | AC 220 V 60 Hz, single-phase, 10 A, 2200 VA |
| Genetic Analyzer Dimension (Closed) | 610 × 532 × 812 mm |
| Genetic Analyzer Dimension (Open) | 1225 × 532 × 812 mm |
| Packing Dimension | Wooden Box: 770 × 692 × 1062 mm Carton: 610 × 430 × 131 mm |
| Genetic Analyzer Net Weight | 95 Kg |
| Gross Weight | Wooden Box: 128 kg Cartoon: 6 kg |
Standard DNA Database Export
RFID-Based Consumable Tracking
Consistent Instrument Performance
Multiple Polymer Options Available
Run Length Customization Support
Our Genetic Analyzer LGA-A11 is frequently using in Forensic Labs for construction of DNA database, especially through Short Tandem Repeat (STR) analysis. Its high throughput and precise fluorescence detection make it ideal for matching DNA profiles in criminal investigations, paternity cases, and missing person identification. This is an ideal analyzer for the analysis of Single Nucleotide Polymorphisms (SNPs), STRs and AFLPs.
Name | Quantity |
| Genetic Analyzer | 1 unit |
| Power cable | 1 unit |
| Internet cable | 1 unit |
| Wireless network card | 1 unit |
| Buffer Reservoir | 3 units |
| Buffer Reservoir Septa | 3 units |
| 96-Well Sample Tray | 3 units |
| 96-Well Septa | 10 units |
| Pump Block Upper Drip Tray | 1 unit |
| Polymer Block Lower Drip Tray | 1 unit |
| Polymer Injection Pump | 1 unit |
| Polymer Lower Block | 1 unit |
| Polymer Tube | 1 unit |
| Syringe | 1 unit |
| Capillary Array, 24-channel (50 cm) | 2 units |
| Polymer separation gel 07 (7ml, 2℃~8℃) | 2 bottle |
| Buffer 10X (28ml, 2℃~8℃) | 1 bottle |
| HD formamide (7ml, -25℃~-15℃) | 1 bottle |
| 6-dye Matrix (6 colors) (50μL, -25℃~-15℃) | 1 bottle |
| Orange 600- Fluorescent DNA size marker (600 bp band) (50μL, -25℃~-15℃) × 1 unit | 1 unit |
| Spectral Calibration Kit (15μL-25℃~-15℃) | 1 unit |
Name | Quantity | Usage Guideline | Function |
96-well PCR plate | Pack (10 pieces) | - | 200UL ,96-Well |
16-Well,Buffer Reservoir Septa | Pack (20 pieces) | - | Adhesive septa for use with buffer reservoir |
96-Well Septa | Pack (10 pieces) | - | Sampling septa for use with 96-well plates |
24-capillary array (36 cm) | Set (36 cm) | Replace after every 200 uses | Containers for electrophoresis for fragment |
24-capillary array (50 cm) | Set (50 cm) | Replace after every 200 uses | Containers for electrophoresis for fragment |
Buffer 10X | Bottle (500 mL) | Change once a week, 5 mL each time | Provides ion concentration and maintains pH |
HiDi Formamide | Bottle (25 mL) | Suitable for about 2500 samples | Denaturant that prevents the sequencing |
Polymer separation gel 05 | Bottle (3.5 mL) | Change every week and add at least 1.5 ml each time | Can be used for genetic analysis on |
Polymer separation gel 07 | Bottle (28 mL) | Change every week and add at least 1.5 ml each time | used for genetic analysis on sequencers |
Orange500- Fluorescent DNA size marker (500 bp band) | Set (120 µL × 2) | Suitable for about 200 experiments | Used as a molecular weight internal standard |
Orange600- Fluorescent DNA size marker (600 bp band) | Piece (50 µL) | Suitable for about 220 experiments | Used as a molecular weight internal standard |
SG Terminator V1.8 Cycle Sequencing Kit (192 µL) | Piece (192 µL) | Suitable for 24 reactions | Sanger sequencing cycle sequencing uses |
SG Terminator V1.8 Cycle Sequencing Kit (800 µL) | Piece (800 µL) | Suitable for 100 reactions | Sanger sequencing cycle sequencing uses |
SG Terminator V1.8 Cycle Sequencing Kit (8000 µL) | Piece (8000 µL) | Suitable for 1000 reactions | Sanger sequencing cycle sequencing uses |
SG Terminator V1.8 Cycle Sequencing Kit (2 Bottles) | Bottle (2 × 20 mL) | Suitable for 5000 reactions | Sanger sequencing cycle sequencing uses |