High Speed Centrifuge LHS-C30 achieves a maximum speed of 18500 rpm with an accuracy of ± 10 rpm. It features an LCD screen that clearly displays all operating parameters for a reliable operation. The centrifuge supports both swing-out and fixed angle rotors, accommodating a wide range of sample types. Its various safety features such as automatic rotor recognition and gas hinge prevents overspeed and sudden door falls. Our centrifuge is specifically designed for processing large sample volumes requiring high-speed centrifugation.
| Max Speed | 18500 rpm |
| Speed Accuracy | ± 10 rpm |
| Max RCF | 24760 × g |
| Capacity | 4 × 500 mL |
| Timing Range | 1 sec to 9999 min 59 sec |
| Timing Increment | 1 sec |
| Display | LCD |
| Noise | Up to 60 dB (A) |
| ACC/DEC Rates | 19 rates |
| Programs | 12 |
| Power Consumption | 750 W |
| Dimension | 550 × 450 × 390 mm |
| Net Weight | 49 kg |
Automatic RPM/RCF conversion
Motorized electronic door lock
Variable frequency motor drive
Durable steel housing
Autoclavable rotors
Our High Speed Centrifuge LHS-C30 is ideal for high-volume sample processing in clinical, research, and industrial laboratories. It is widely used for blood separation, cell harvesting, and sample preparation involving conical tubes, bottles, and well plates.
Name | Max. Speed | Max. RCF | Capacity | Tube Size |
| Fixed Angle Rotor 01 | 18500 | 23800 × g | 12 × 1.5/2.2 mL | Ø11 × 42 mm |
| Fixed Angle Rotor 02 | 15000 | 18270 × g | 12 × 5 mL | Ø14 × 54 mm |
| Fixed Angle Rotor 03 | 15000 | 21630 × g | 24 × 1.5/2.2 mL | Ø11 × 42 mm |
| Fixed Angle Rotor 04 | 16000 | 24760 × g | 24 × 1.5/2.2 mL (Aerosol Tight) | Ø11 × 42 mm |
| Fixed Angle Rotor 05 | 13000 | 15620 × g | 12 × 10 mL | Ø16 × 86 mm |
| Fixed Angle Rotor 06 | 13000 | 15620 × g | 36 × 1.5/2.2 mL | Ø11 × 42 mm |
| Fixed Angle Rotor 07 | 13000 | 15620 × g | 8 × 15 mL | Ø17 × 121 mm |
| Fixed Angle Rotor 08 | 12000 | 15970 × g | 6 × 50 mL Conical Bottom | Ø29 × 116 mm |
| Fixed Angle Rotor 09 | 12000 | 15970 × g | 6 × 50 mL Round Bottom | Ø29 × 111 mm |
| Fixed Angle Rotor 10 | 12000 | 15970 × g | 48 × 1.5/2.2 mL | Ø11 × 42 mm |
| Fixed Angle Rotor 11 | 10000 | 10640 × g | 4 × 100 mL | Ø38 × 123 mm |
| Fixed Angle Rotor 12 | 10000 | 10640 × g | 8 × 50 mL Conical Bottom | Ø29 × 116 mm |
| Fixed Angle Rotor 13 | 10000 | 10640 × g | 8 × 50 mL Round Bottom | Ø29 × 111 mm |
| Fixed Angle Rotor 14 | 10000 | 10640 × g | 12 × 15 mL | Ø17 × 112 mm |
| Fixed Angle Rotor 15 | 10000 | 11045 × g | 6 × 100 mL | Ø16 × 86 mm |
| Microplate Rotor 01 | 4000 | 1970 × g | 2 × 3 × 96 Well Plate | 128 × 87 × 60 mm |
| Microplate Rotor 02 | 4000 | 3400 × g | 4 × 2 × 96 Well Plate | 128 × 87 × 60 mm |
| Swing Out Rotor 01 | 4000 | 3100 × g | 4 × 250 mL | Ø63 × 121 mm |
| Swing Out Rotor 02 | 4000 | 3100 × g | 48 × 2 to 7 mL (Blood Tube) | Ø13 × 75 to 100 mm |
| Swing Out Rotor 03 | 4000 | 3100 × g | 64 × 2 to 7 mL (Blood Tube) | Ø13 × 75 to 100 mm |
| Swing Out Rotor 04 | 4000 | 3400 × g | 4 × 500 mL | 80 × 137 mm |
| Swing Bucket Rotor 01 | 4000 | 3400 × g | 20 × 50 mL | 29.5 × 116 mm |
| Swing Bucket Rotor 02 | 4000 | 3400 × g | 40 × 15 mL | 17 × 121 mm |
| Swing Bucket Rotor 03 | 4000 | 3400 × g | 80 × 10 mL (Blood Tube) | 15 × 100 mm |
| Swing Bucket Rotor 04 | 4000 | 3400 × g | 112 × 2 to 7 mL (Blood Tube) | Ø13 × 75 to 100 mm |
| Swing Bucket Rotor 05 | 4000 | 3400 × g | 100 × 1.5 mL | 11 × 42 mm |
| Swing Bucket Rotor 06 | 4000 | 3400 × g | 148 × 5 mL (RIA Tube) | Ø13 × 75 to 100 mm |
| Swing Bucket Rotor 07 | 4000 | 3400 × g | 96 × 2 to 7 mL (Blood Tube) | Ø13 × 75 to 100 mm |
Name | Max. Speed | Max. RCF | Capacity | Tube Size |
| Adapter 01 | 4000 | 3100 × g | 8 × 50 mL | 29.5 × 116 mm |
| Adapter 02 | 4000 | 3100 × g | 20 × 15 mL | 17 × 121 mm |
| Adapter 03 | 4000 | 3100 × g | 36 × 100 mL | Ø16.5 × 86 to 100 mm |
| Adapter 04 | 4000 | 3100 × g | 40 × 7 mL Blood Tube | Ø13 × 100 mm |
| Adapter 05 | 4000 | 3400 × g | 16 × 50 mL Normal | 29 × 116 mm |
| Adapter 06 | 4000 | 3400 × g | 16 × 50 mL Aerosol Tight | 29 × 116 mm |
| Adapter 07 | 4000 | 3400 × g | 36 × 15 mL Normal | 17 × 121 mm |
| Adapter 08 | 4000 | 3400 × g | 36 × 15 mL Aerosol Tight | 17 × 121 mm |
| Adapter 09 | 4000 | 3400 × g | 76 × 2 to 7 mL Blood Tube Normal | Ø13 × 75 to 100 mm |
| Adapter 10 | 4000 | 3400 × g | 76 × 2 to 7 mL Blood Tube Aerosol Tight | Ø13 × 75 to 100 mm |